Display Type: OLED display
SP02 Measurement Range: 70%-100%
Accuracy +/-2% on the stage of 70% - 99%
Pulse Range Measurement Range: 25 – 250 BPM
Accuracy +/-1BPM or +/-1% (larger)
Quantity: | |
---|---|
![]() | Display Type: OLED display SP02 Measurement Range: 70%-100% Accuracy +/-2% on the stage of 70% - 99% Pulse Range Measurement Range: 25 – 250 BPM Accuracy +/-1BPM or +/-1% (larger) |
Power Requirement: Two AAA 1.5V alkaline batteries - Voltage range: 2.6 - 3.6V
Low Consumption: Less than 30mA Measurement Accuracy: SpO2 Accuracy +/-2% on the stage of 70% - 99% - No definition of less than 70% - Pulse rate +/-1BPM or +/-1% (larger) Measurement Performance in Low Perfusion Condition: The pulse wave is available without failure when the simulation pulse wave amplitude is at 6%
Anti-interference ability of ambient light: Natural light in indoor lighting and the existing oxygen measurements under dark conditions with the measured values compared to less than 1%.
The product will automatically be powered off when no signal is in the product for longer than 8 seconds.
Dimension Length: 58 mm, Width: 32mm - Weight: 54g (including two AAA batteries)
Environment Requirements: Operation Temperature: 40° F - 104°F Storage Temperature: 50° F - 104°F |
Problems | Possible reason | Solution |
SpO2% or pulse rate can not be shown normally | 1. Finger is not plugged correctly 2. Patient’s SpO2value is too low to be measured | 1.Retry by plugging the finger 2. There is excessive illumination 3. Measure more times, If you can make sure about no problem existing in the product. Please go to a hospital timely for exact diagnosis |
SpO2% or pulse rate is shown unstably | 1. Finger might not be plugged deep enough 2. Excessive patient movement | 1. Retry by plugging the finger 2. Be calmness. |
The Monitor can not be powered on | 1.No battery or low power of battery 2.Battery might be installed incorrectly 3. The Monitor might be damaged | 1. Please replace battery 2. Please reinstall the battery 3. Please contact with local customer service centre |
Indication is suddenly off | 1.The Oximeter is automatically powered off when no signal is detected longer than 8 seconds 2. The batteries power is too low to work | 1. Normal 2. Replace the battery |
“Error3” or “Error4” Displayed on screen | 1. Err 3 means the red emission LED is damaged. 2. Err 4 means the infra-red emission LED is damaged. | 1. Check the red emission LED 2. Check the infra-red emission LED |
“Error 6” | Err 6 means the crystal is failure | Change the crystal |
“Error7” displayed on screen | Err 7 means all the emission LED or reception dioxide is damaged. | Check the emission LED and reception dioxide. |
Guidance and Manufacture’s declaration - electromagnetic emission | ||
Guidance and Manufacture’s declaration – electromagnetic environment specified below. The customer of the user of the Pulse Oximeter should assure that it is used in such and environment. | ||
Emission test | Compliance | Electromagnetic Environment – guidance |
RF emissions CISPR 11 | Group 1 | The pulse Oximeter uses RF energy only for very low and is not likely to cause interference in nearby electronic equipment. |
RF emissions CISPR 11 | Class B | The pulse Oximeter is suitable for use in all establishments, incluing domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. |
Harmonic emissions IEC 61000-3-2 | Not Applicable | |
Voltage fluctuations/ flicker emissions IEC 61000-3-2 | Not Applicable |
![]() | Display Type: OLED display SP02 Measurement Range: 70%-100% Accuracy +/-2% on the stage of 70% - 99% Pulse Range Measurement Range: 25 – 250 BPM Accuracy +/-1BPM or +/-1% (larger) |
Power Requirement: Two AAA 1.5V alkaline batteries - Voltage range: 2.6 - 3.6V
Low Consumption: Less than 30mA Measurement Accuracy: SpO2 Accuracy +/-2% on the stage of 70% - 99% - No definition of less than 70% - Pulse rate +/-1BPM or +/-1% (larger) Measurement Performance in Low Perfusion Condition: The pulse wave is available without failure when the simulation pulse wave amplitude is at 6%
Anti-interference ability of ambient light: Natural light in indoor lighting and the existing oxygen measurements under dark conditions with the measured values compared to less than 1%.
The product will automatically be powered off when no signal is in the product for longer than 8 seconds.
Dimension Length: 58 mm, Width: 32mm - Weight: 54g (including two AAA batteries)
Environment Requirements: Operation Temperature: 40° F - 104°F Storage Temperature: 50° F - 104°F |
Problems | Possible reason | Solution |
SpO2% or pulse rate can not be shown normally | 1. Finger is not plugged correctly 2. Patient’s SpO2value is too low to be measured | 1.Retry by plugging the finger 2. There is excessive illumination 3. Measure more times, If you can make sure about no problem existing in the product. Please go to a hospital timely for exact diagnosis |
SpO2% or pulse rate is shown unstably | 1. Finger might not be plugged deep enough 2. Excessive patient movement | 1. Retry by plugging the finger 2. Be calmness. |
The Monitor can not be powered on | 1.No battery or low power of battery 2.Battery might be installed incorrectly 3. The Monitor might be damaged | 1. Please replace battery 2. Please reinstall the battery 3. Please contact with local customer service centre |
Indication is suddenly off | 1.The Oximeter is automatically powered off when no signal is detected longer than 8 seconds 2. The batteries power is too low to work | 1. Normal 2. Replace the battery |
“Error3” or “Error4” Displayed on screen | 1. Err 3 means the red emission LED is damaged. 2. Err 4 means the infra-red emission LED is damaged. | 1. Check the red emission LED 2. Check the infra-red emission LED |
“Error 6” | Err 6 means the crystal is failure | Change the crystal |
“Error7” displayed on screen | Err 7 means all the emission LED or reception dioxide is damaged. | Check the emission LED and reception dioxide. |
Guidance and Manufacture’s declaration - electromagnetic emission | ||
Guidance and Manufacture’s declaration – electromagnetic environment specified below. The customer of the user of the Pulse Oximeter should assure that it is used in such and environment. | ||
Emission test | Compliance | Electromagnetic Environment – guidance |
RF emissions CISPR 11 | Group 1 | The pulse Oximeter uses RF energy only for very low and is not likely to cause interference in nearby electronic equipment. |
RF emissions CISPR 11 | Class B | The pulse Oximeter is suitable for use in all establishments, incluing domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. |
Harmonic emissions IEC 61000-3-2 | Not Applicable | |
Voltage fluctuations/ flicker emissions IEC 61000-3-2 | Not Applicable |